herpy
Topics

Lighting and UVB

How light and UVB radiation work in the terrarium: who needs what, which bulbs and tubes exist, how far from the animal they should be, when to replace them, and how the radiation is measured. For everyone who has to choose lighting for reptiles and amphibians.

Why light matters

Light in a terrarium has three jobs. It governs the daily rhythm, it lets the animal see and find its way around, and for many species it is the source of vitamin D3. A regular alternation between light and dark is a cornerstone of good care: constant light disturbs rest and stresses the animal.

Day length follows the species' way of life and homeland. As a broad rule of thumb, 12 hours of light and 12 hours of dark suit most species, while diurnal species from open landscapes can have 12-16 hours of light. Species that go through an annual cycle get shorter days in winter and longer in summer; the figures are in the species guide. A timer on the socket makes the daily rhythm stable and is the cheapest improvement a terrarium can get. A gradual transition between day and night, for example with a dimmer, is better than all the light going out at once.

Animals use the light actively. Diurnal species such as Phelsuma grandis and Varanus prasinus move up towards the light and shift between sun and shade during the day. Nocturnal species such as Eublepharis macularius lie hidden by day but still get a little daylight at dusk and in the opening of the hide. No nocturnal species lives entirely without light.

Light and heat are connected but must be controllable separately. If the only heat source is a bulb that shines, the heat disappears when the light goes out in the evening. Nocturnal and crepuscular species need dim light and many hides, not just a dark corner.

Read more: Calcium, vitamins and supplements

UVB, vitamin D3 and bones

UVB is the part of the sun's ultraviolet radiation that makes the skin produce vitamin D3. In the skin, provitamin D3 is converted to previtamin D3, which body heat then rearranges into D3. The liver converts D3 further into 25-hydroxyvitamin D, which is the substance used to measure the animal's vitamin D status. Only a narrow band of the UVB radiation is effective, and with prolonged exposure part of the previtamin D3 is converted into inactive substances, so that the body does not overproduce.

D3 governs the absorption of calcium from the gut. If it is lacking, or the food is poor in calcium, the animal can develop metabolic bone disease: soft, bent bones, tremors, deformed jaws and, at worst, fractures and paralysis. The disease affects young, fast-growing animals and egg-laying females in particular. Supplementing D3 in the food helps, but it is hard to hit the right dose, and insects contain almost no D3 of their own.

In Tiliqua scincoides, food with D3 but without UVB gives low levels of 25-hydroxyvitamin D in the blood. Four weeks of UVB, either 2 or 12 hours a day, multiplies the levels, and without UVB it then takes more than 4 and more than 7 months before they are back to the starting level. UVB thus works, a couple of hours a day go a long way, and the store does not last for ever.

You cannot tell by looking at an animal whether it is getting enough. The symptoms come late. UVB is therefore about prevention: give species that use the sun in the wild a suitable dose every day, and let the animal choose how much it wants by providing shade in the terrarium.

Read more: Common diseases and signs of illness

Ferguson zones and the UV index

Species are divided into four zones according to how much sun they seek in the wild. The division is called Ferguson zones and is widely used to choose UVB lamps. For each zone there are two figures: the average UV index in the places where the animal stays, and the highest index the animal seeks. The first suits as a background level in the terrarium, the second is a ceiling for what the animal may receive closest to the lamp.

  • Zone 1: crepuscular and nocturnal animals and species that live in shade. Average 0-0.7, maximum 0.6-1.4. Examples: Correlophus ciliatus and Agalychnis callidryas.
  • Zone 2: species that bask occasionally or in dappled sun. Average 0.7-1.0, maximum 1.1-3.0. Examples: Eublepharis macularius and Lygodactylus williamsi.
  • Zone 3: diurnal species that bask in open or partial sun. Average 1.0-2.6, maximum 2.9-7.4. Examples: Phelsuma lineata and Varanus prasinus.
  • Zone 4: species that bask in full sun in the middle of the day, for example in desert and savanna. Average 2.6-3.5, maximum 4.5-9.5.

The UV index is the same figure the weather forecast uses. In the tropics and subtropics it is 3-5 in open sun in the morning, when most animals bask longest, and that is a suitable level at the basking spot for species in zones 3 and 4. Under artificial light the index at the animal should not exceed 7-8, even in zone 4, because the lamps' spectrum is not the same as the sun's.

Zones 1 and 2 do best with a low level across a large part of the terrarium. Zones 3 and 4 need a defined basking spot with higher radiation, like a patch of sunlight. All zones need shade, where the index is near zero. Albinos and other pale colour variants lack the melanin that protects against UV and should get less than the species' zone.

Read more: Heat and temperature

Fluorescent tubes, compact bulbs and metal halide

There are three types of UVB source for terrariums, and they give very different distributions of radiation.

  • Fluorescent tubes (T8 and T5). A tube gives an even, broad radiation over a long surface. T8 tubes give a low level close to the tube, corresponding to shade on a sunny day, and suit zones 1 and 2 in smaller terrariums. High-output T5 tubes (T5-HO) are far stronger and can sit further away: a strong T5-HO tube with a reflector can give a UV index of 0.5-1.0 over an area of more than a metre at a distance of 85 cm. Closer, T5-HO also gives basking-spot levels for zones 3 and 4.
  • Compact bulbs (spiral bulbs). They fit ordinary sockets, but output varies greatly between makes, and the radiation covers a smaller area than a tube. Use them only if the index at the animal can be measured.
  • Mercury vapour and metal halide. These bulbs give light, heat and UVB from the same source and are suitable for a basking spot for species in zones 3 and 4, for example Varanus gouldii. The beam can be narrow: a metal halide bulb can give the same UV index at 45 cm as a T5-HO tube with a reflector at 85 cm, but on a spot under 25 cm in diameter. The basking spot must cover the whole animal, so large animals need wider lamps or several. The bulbs get very hot and require suitable sockets.

Terms such as "full spectrum", "natural light" and "daylight" say nothing about UVB, and some bulbs with names like that give almost no UVB. Choose a lamp sold as a UVB lamp, and preferably one whose output has been tested. The same type can give different values from one unit to the next, so measuring is the only sure way.

Distance, mesh and placement

UVB radiation decreases quickly with distance from the lamp, and how quickly depends on the lamp's type and beam shape. The manufacturers' distances are a starting point, not an answer: fixture, reflector, mesh and even branches and leaves change the distribution. Measure at the animal's back when it sits at the basking spot, and adjust the distance until the UV index lies within the zone's range.

The radiation must reach the animal unobstructed. Ordinary window glass of 4 mm lets through under 1% of UVB radiation, and most plastic sheets block it too. A lamp outside a glass terrarium therefore gives the animal almost nothing. The lamp must sit inside the terrarium or above a mesh. A mesh also absorbs part of the radiation, most when the openings are fine and the wires thick. Choose a mesh with large openings, and measure below the mesh before the distance is fixed.

The lamp should sit above the animal, not at the side, so that the shape of the head and the eyelids shade the eyes. Place it along the terrarium's length so that the animal can choose to move out of the radiation. Overlapping beams from several lamps add together, so take care not to gather them over the same spot. All bulbs must be out of the animal's reach, if necessary behind a wire guard, as they can cause both heat and UV burns.

Climbing species move up and down, and the distance to the lamp changes with them. The highest branch under the lamp determines the largest dose, so that is where to measure.

Replacement and maintenance

UVB lamps lose strength long before they stop shining, and the eye cannot see it. The decline is due above all to the glass changing under the UV radiation and to the electrodes blackening the glass at the ends. Good fluorescent tubes lose about a tenth in the first 100 hours and 30-50% after a year of use, corresponding to approximately 4,000 hours at 10-12 hours a day. Poor products can lose almost two thirds in three months and are then without effect at a practical distance.

Without a meter, UVB lamps are replaced every 6-8 months or according to the manufacturer's instructions. Write the date of installation on the fixture.

With a UV index meter you can follow the decline and replace when the index at the animal no longer lies in the desired range, however old the lamp is. Some tubes then last a year or more, others need replacing sooner.

Keep lamps, reflectors and mesh free of dust and limescale. Dust absorbs the UV radiation and converts it to heat. Clean with a dry cloth when the lamp is off and cold, and check sockets and wiring at the same time. Black ends on a tube are a sign of wear.

Amphibians and nocturnal animals

Amphibians have thin skin, which UV radiation penetrates easily, and most belong to zones 1 and 2. Diurnal amphibians probably use UVB for calcium metabolism and for colour vision, and a lack of UVB and D3 in combination with calcium-poor food can cause metabolic bone disease. The light should therefore be dim and the terrarium rich in shade.

Juvenile Pseudophryne pengilleyi are less active at a UV index of around 0.75 than at 0.2, but grow and survive equally well. Even low values thus make amphibians regulate, and shade in foliage, bark and plants is just as important as the lamp. For most amphibians, a UV index under 1 where the animal comes closest to the lamp is suitable.

Diurnal amphibians such as Oophaga pumilio and Mantella aurantiaca can have a weak T8 or T5 tube, placed so that the index at the animal stays under 1, and a densely planted terrarium. Nocturnal amphibians such as Agalychnis callidryas and Theloderma corticale manage with D3 and calcium in the food, but a weak UVB source with plenty of shade does no harm. Fluorescent tubes and LEDs suit amphibians best, because they give little heat.

Among nocturnal reptiles, Eublepharis macularius can absorb enough calcium from its food to avoid metabolic bone disease without UVB. Vitamin D has other roles in the body as well, however, and nocturnal animals make D3 in the skin when they receive daylight. There is therefore no reason to withhold UVB from nocturnal species, as long as they have a hide and receive only a low level corresponding to zone 1.

Measuring with a UV index meter

The only way to know what the animal actually receives is to measure. Data sheets and the manufacturers' tables can be misleading, because the radiation depends on fixture, reflector, mesh, age and distance.

A UV index meter shows a figure in UV index, and its sensitivity lies close to the spectrum that produces D3 in the skin. That makes it suitable for the terrarium. Broadband UVB meters respond to the whole UVB range, including the wavelengths that do not produce D3, and different models show different figures for the same lamp. A meter is an investment, but one meter can easily be shared between several keepers.

How to measure:

  • Let the lamp burn for half an hour so that it has reached full strength.
  • Hold the meter level with the animal's back when it sits at the basking spot, and point the sensor at the lamp.
  • Measure in several places: at the basking spot, beside it, in the shade and at the bottom. Write the values down.
  • Measure again at regular intervals so that the decline in strength can be followed.
  • Measure after every change: new lamp, new distance, new reflector or new branches.

Compare the figures with the species' zone. If the meter shows more than the zone tolerates, raise the lamp. If it shows less, lower the lamp, or replace it. Always measure in the terrarium's shade as well, so that the animal has a place where the radiation is near zero.

Sources

  1. How much UVB does my reptile need? The UV-Tool, a guide to the selection of UV lighting for reptiles and amphibians in captivity. Journal of Zoo and Aquarium Research, 2016
  2. Measuring the Rise and Fall of Plasma 25-Hydroxyvitamin D Concentrations in Blue-Tongued Skinks (Tiliqua scincoides) Following UVB Exposure. Veterinary Sciences, 2025
  3. Effects of ultraviolet radiation on the activity, survival, and growth of the critically endangered northern corroboree frog. Biology Open, 2025
  4. Guidelines for Inspection of Companion and Commercial Animal Establishments. Frontiers in Veterinary Science, 2018
  5. Management and Husbandry of Reptiles. Merck Veterinary Manual, 2026
  6. Environment and Husbandry for Amphibians. Merck Veterinary Manual, 2026
Found a mistake? Suggest a correction

Tell us what is wrong and what it should say. We read every suggestion and correct the page once we have checked it.